The main compressed air pipeline shall be made of PB material, with a nominal diameter of DN20 and hot‑fusion joints. The design working pressure of the compressed air pipeline shall be ≥7–8 kgf/cm².
Category:
Keywords:
Central Collection Room
Air compressor system: operating output pressure ≥ 0.6–0.85 MPa; air receiver tank capacity ≥ 0.6 m³.
The main compressed air pipeline shall be made of PB material, with a nominal diameter of DN20 and hot‑fusion joints. The design working pressure of the compressed air pipeline shall be ≥7–8 kgf/cm².
The central computer room is equipped with a soundproofing and noise-reduction system, featuring fully enclosed fan silencers. The silencer’s sound‑insulating modules have a thickness of no less than 125 mm, with a finish of nationally standard hot‑dip galvanized steel sheet coated with electrostatic powder paint. The silencer is designed for easy disassembly.
The central computer room is equipped with a sprinkler‑based deodorization and disinfection system. Inside the room, an atomizing disinfection and deodorization unit is installed to control and eliminate odors and pathogenic microorganisms from waste. The spray piping is made of stainless steel with a wall thickness of ≥1 mm, and the nozzles are spaced ≤1.5 m apart. Spraying is directed diagonally downward from elevated positions to ensure 100% coverage of the work area.